20A/200A AC/DC Clamp Meters with Analog Output and Peak Hold for Inrush Measurement Applications
DESCRIPTION
MODEL NO. (ORDER CODE)
3284 | with monitor/analog output |
---|
Hioki clamp meters are best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. The 3284 is an AC/DC current and voltage clamp meter with analog output capabilities and a peak hold function.
KEY FEATURES
• Analog output for current measuring level, current measuring waveform, or frequency measuring level.
• Peak hold function displays the crest value of the inrush current occurring when electrical equipment starts
• AC+DC mode enables measurement of the RMS value of full- or half-wave rectified waveforms
BASIC SPECIFICATIONS (ACCURACY GUARANTEED FOR 1 YEAR, POST-ADJUSTMENT ACCURACY GUARANTEED FOR 1 YEAR)
DC current | 20.00/ 200.0 A, Basic accuracy: ±1.3 % rdg. ±3 dgt. |
---|---|
AC current | 20.00/ 200.0 A (10 Hz to 2 kHz, True RMS), Basic accuracy 45-66 Hz: ±1.3 % rdg. ±3 dgt. |
DC voltage | 30.00 V to 600 V, 3 ranges, Basic accuracy: ±1.0 % rdg. ±3 dgt. |
AC voltage | 30.00 V to 600 V, 3 ranges (10 to 1 kHz, True RMS), Basic accuracy 45-66 Hz: ±1.0 % rdg. ±3 dgt. |
Crest factor | 2.5 or less (1.5 at 200 A, 1.7 at 600 V) |
Monitor, Analog output | DC, or AC 1 V/ f.s., Level output, Waveform output: DC to 20 kHz bandwidth (±3dB) |
Resistance, Continuity check | N/A |
Frequency | 1.00 Hz to 1000 Hz, Basic accuracy: ±0.3 % rdg. ±1 dgt. |
Other functions | AC+DC mode, Maximum/ Minimum/ Average value record function, Data hold, Peak hold, Auto power off, Auto zero |
Display | Display refresh rate: 4 times/s (FAST), 1 time/3s (SLOW), 4 times/s (bar graph) |
Power supply | 6F22 (Stacked manganese battery) ×1, Continuous use: 25 hours, or AC adapter 9445-02/-03 |
Core jaw dia. | φ 33 mm (1.30 in) |
Dimensions and mass | 62 mm (2.44 in) W × 230 mm (9.06 in) H × 39 mm (1.54 in) D, 460 g (16.2 oz) |
Accessories | Test Lead L9207-10 ×1, Carrying Case 9399 ×1, Hand strap ×1, 6F22 (Stacked manganese battery) ×1, Instruction manual ×1 |
CATALOGS
CLAMP METER SERIES -SERIES_CLAMPMETERS_E10-1ZM
USER GUIDES
CLAMP TESTER SERIES SELECTION GUIDE
MANUALS
CLAMP ON AC/DC HITESTER 3284 [1MB]
OPTIONS
Bundled Accessories
CARRYING CASE 9399
Leak Current
*For commercial power lines, 50/60 Hz
AC ADAPTER 9445-02
For USA, 100 to 240 V AC, 9 V/ 1 A
OUTPUT CORD 9094
3.5 mm (0.14 in) dia. mini plug to banana, 1.5 m (4.92 ft) length
AC ADAPTER 9445-03
For EU 100 to 240 V AC, 9 V/ 1 A
Other options for Input
CONVERSION ADAPTER 9199
Receiving side banana, output BNC terminal
Test leads A
Options for the L9207-10
TEST LEAD L9207-10
90 cm (2.95 ft) length