CLAMP ON LEAK HiTESTER 3283

CLAMP ON LEAK HiTESTER 3283

CLAMP ON LEAK HiTESTER 3283

1mA to 200A AC Leakage Current Clamp Meter with 10 µA Resolution to Analyze Distorted Waveforms

DESCRIPTION

Hioki clamp meters are best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. The Hioki 3283 series are leakage current handheld clamp meters with a 10mA to 200A range and 10 μA resolution. Model 3283 has output capabilities for advanced monitoring on recording equipment, and Model 3283-20 complies with EN 61010-2-032:2012 Type A standards to measure uninsulated hazardous live conductors such as busbars.

CAT III 300 V: 3283-20

KEY FEATURES

• Measure leak current using highly sensitive 10μA resolution (at 10.00 mA range)
• Indicate 50/60 Hz leak current components with the filtering function
• Monitor leak current conditions in combination with a Memory HiCorder (monitor output, Model 3283 only)
• 3283-20: EN 61010-2-032:2012 Type A to measure uninsulated
hazardous live conductors such as busbars

MODEL NO. (ORDER CODE)

3283Not CE marked, with monitor/analog output
CE
DC
TrueRMS
Not CE

BASIC SPECIFICATIONS (ACCURACY GUARANTEED FOR 1 YEAR, POST-ADJUSTMENT ACCURACY GUARANTEED FOR 1 YEAR)

 32833283-20
AC Current10.00 m/ 100.0 m/ 1.000/ 10.00/ 200.0 A, 5 ranges, (40 Hz to 2 kHz, True RMS), Basic accuracy: ±1.0 % rdg. ±5 dgt.
AC VoltageN/A
Frequency30.0 Hz to 1000 Hz, 2 ranges, Basic accuracy: ±0.3 % rdg. ±1 dgt.
Crest factor2.5 or less (1.5 at 200 A range)
Filter functionCut off frequency at filter ON: 180 Hz (-3dB)
OutputREC output for current: DC 1 V/f.s. (2 V/f.s. at only 200 A range), response time: less than 200 ms.
MON output for current: AC 1 V/f.s. (2 V/f.s. at only 200 A range), 5 Hz to 15 kHz frequency bandwidth (-3 dB)
N/A
Other functionsMax./ Min./ Average value record, Data hold, Auto power off
DisplayLCD, max. 2000 dgt., Display refresh rate: 4 times/s (Fast), 1 time/3s (Slow), 4 times/s (bar graph)
Power supply6LR61 (Stacked alkaline battery) ×1, or 6F22 (Stacked manganese battery), Continuous use: 40 hours (using 6F22),
AC adapter 9445-02/-03
6LR61 (Stacked alkaline battery) ×1, or 6F22 (Stacked manganese battery), Continuous use: 40 hours (using 6F22)
Core jaw dia.φ 40 mm (1.57 in)
Dimensions and mass62 mm (2.44 in) W × 225 mm (8.86 in) H × 39 mm (1.54 in) D,
400 g (14.1 oz)
AccessoriesCarrying case 9399 ×1, Hand strap ×1, Stacked manganese battery (6F22) ×1, Instruction manual ×1Carrying case 9399 ×1, Hand strap ×1, Alkaline battery (6LR61) ×1, Instruction manual ×1

CATALOGS

CLAMP ON HITESTER SERIES 

DOWNLOAD

CLAMP ON LEAK HITESTER 3283-20 

DOWNLOAD

USER GUIDES

CLAMP TESTER SERIES SELECTION GUIDE 

DOWNLOAD

MANUALS

CLAMP ON LEAK HITESTER 3283 [8MB] 

DOWNLOAD

CLAMP ON LEAK HITESTER 3283-20 [3MB] 

DOWNLOAD

CLAMP ON LEAK HITESTER 3283-20 [3MB] 

DOWNLOAD

DECLARATION OF CONFORMITY

CLAMP ON LEAK HITESTER 3283-20 [121KB] 

DOWNLOAD

OPTIONS

Bundled Accessories

CARRYING CASE 9399

Leak Current

*For commercial power lines, 50/60 Hz

AC ADAPTER 9445-02

For USA, 100 to 240 V AC, 9 V/ 1 A

OUTPUT CORD 9094

3.5 mm (0.14 in) dia. mini plug to banana, 1.5 m (4.92 ft) length

AC ADAPTER 9445-03

For EU 100 to 240 V AC, 9 V/ 1 A

Other options for Input

CONVERSION ADAPTER 9199

Receiving side banana, output BNC terminal