50A Voltage Output Sensor for Current Load Measurements
DESCRIPTION
MODEL NO. (ORDER CODE)
9695-02 | For the PW3198 or other |
---|
Hioki current sensors are best-in-class devices for use with power meters, PQAs and Memory HiCorders. The 9695-02 is a 50A AC voltage output clamp sensor for measuring load current.
KEY FEATURES
• 40 Hz to 5 kHz bandwidth
• Phase: 45 Hz to 5 kHz
• Rated 50A AC
• 10 mV AC /A output
• φ15 mm (0.59 in) dia.
• Connect to the data acquisition equipment using the 9219 Connection Cord
BASIC SPECIFICATIONS (ACCURACY GUARANTEED FOR 1 YEAR, POST-ADJUSTMENT ACCURACY GUARANTEED FOR 1 YEAR)* F.S. IS THE SENSORʼS RATED PRIMARY CURRENT VALUE.
Primary current rating | 50 A AC |
---|---|
Max. allowable input | Continuous 60 Arms (45 to 66 Hz) |
Output voltage | AC 10 mV/ A |
Amplitude accuracy | ±0.3 % rdg. ±0.02 % f.s. (45 to 66 Hz) |
Phase accuracy | ±2° (45 to 5 kHz) |
Frequency characteristics | 40 Hz to 5 kHz: ±1.0 % (Amplitude deviation from accuracy) |
Max. rated voltage to earth | Less than 300 Vrms (Insulated conductor) |
Core diameter | φ 15 mm (0.59 in) |
Power supply | Not required |
Dimensions and mass | 50.5 mm (1.99 in) W × 58 mm (2.28 in) H × 18.7 mm (0.74 in) D, 50 g (1.8 oz) |
Output terminal : M3 terminal (outside 3 mm, 0.12 inch diameter) Option: Connection cable 9219 (3 m, 9.84 ft length) |
OPTIONS
Current sensors (AC load)
CONNECTION CABLE 9219
Connect with the 9695-02/ -03, Output BNC terminal, 3m (9.84ft) length
Options
CLAMP SENSOR CABLE 9238
For the 9695, 3 m twisted-pair cable with round clipping terminal