Compact, dual-band 120Hz/1kHz LCR Meter for Integration into Automated Production Lines
DESCRIPTION
MODEL NO. (ORDER CODE)
3511-50 |
---|
Note: This product is not supplied with measurement probes or test fixtures. Please select and purchase the measurement probe or test fixture options appropriate for your application separately. For an RS-232C connection: A crossover cable for interconnection can be used. You can use the RS-232C CABLE 9637 without hardware flow control.
Hioki LCR Meters and Impedance Analyzers range from 1mHz to 3GHz devices to suit a wide range of applications in the testing of electronic components. The 3511-50 is a compact, general purpose LCR meter for on-board testing of capacitors and coils used in electrical equipment and devices such as automotive-related components.
KEY FEATURES
• High speed measurement: 5 ms (1 kHz) or 13 ms (120 Hz)
• Built-in high-speed comparator
• Measurement frequency: 1 kHz/120 Hz selectable
• From minute measurement with a maximum resolution of 0.01 pF to high-capacity measurement up to 1 F
• Print measured values and comparator results with the Printer 9442 (option)
BASIC SPECIFICATIONS (ACCURACY GUARANTEED FOR 6 MONTHS, POST-ADJUSTMENT ACCURACY GUARANTEED FOR 6 MONTHS)
Measurement parameters | |Z|, θ, R, C, L, D (tanδ), Q |
---|---|
Measurement range | |Z|, R: 10 mΩ to 200.00 MΩ θ: -90.00° to +90.00° C (at 120 Hz): 9.40 pF to 999.99 mF, C (at 1 kHz): 0.940 pF to 99.999 mF L (at 120 Hz): 14.00 µH to 200.00 kH, L (at 1 kHz): 1.600 µH to 20.000 kH D: 0.0001 to 1.9900, Q: 0.85 to 999.99 |
Basic accuracy | |Z| : ±0.08 % rdg. θ: ±0.05° |
Measurement frequency | 120 Hz or 1 kHz |
Measurement signal level | 50 mV, 500 mV, 1 V rms |
Output impedance | 50 Ω |
Display | LED (5-digit display, full-scale count depends on range) |
Measurement time | Fast: 13 msec, Normal: 90 msec, Slow: 400 msec. (at 120 Hz) Fast: 5 msec, Normal: 60 msec, Slow: 300 msec. (at 1 kHz) |
DC bias | DC voltage/DC current can be superimposed on the measurement signal. (Requires optional unit and external constant voltage source/constant current source.) |
Functions | Panel save and load function, External input/Output (EXT. I/O), GP-IB (option) or RS-232C interface |
Power supply | Selectable 100, 120, 220 or 240V AC ±10%, 50/60Hz, 20VA max. |
Dimensions and mass | 210 mm (8.27 in) W × 100 mm (3.94 in) H × 168 mm (6.61 in) D, 2.5 kg (88.2 oz) |
Accessories | Instruction manual × 1, Power cord × 1, Spare fuse × 1 |
CATALOGS
CATALOG: LCR METER SERIES
LCR HITESTER 3511-50
SMD TEST FIXTURE IM9110
IMPEDANCE ANALYZER IM7580 SERIES
USER GUIDES
LCR APPLICATION GUIDE
DECLARATION OF CONFORMITY
LCR HITESTER 3511-50 [100KB]
OPTIONS
Connection Options
* L9217: for motor analysis input
CONNECTION CABLE 9444
9 pin – 9 pin straight, 1.5 m (4.92 ft) length
Other options for Input
CONNECTION CORD 9165
Cord has metallic BNC connectors at both ends, use at metallic terminal, 1.5 m (4.92 ft) length
PC communication
*The 9151-02 is only for the RM3545-01
GP-IB INTERFACE 9518-01
Built into rear panel
GP-IB CONNECTOR CABLE 9151-02
2 m (6.56 ft) length
Printer options
*PRINTER UNIT is a built-in option that must be specified upon order.
AC ADAPTER 9443-02
For the Printer 9442, EU type
PRINTER 9442
For printing numerical values 112 mm (4.41 in) paper width, not CE marked
RECORDING PAPER 1196
For the Printer 9442, 112 mm (4.41 in) × 25 m (82.03 ft), 10 rolls/set
Probe and Test fixtures
SMD TEST FIXTURE IM9110
• Direct connection two-terminal measurement type • DC to 1 MHz • Measurable sample sizes: 008004 (EIA)
DC BIAS CURRENT UNIT 9269
42 Hz to 100 kHz, Max. allowable current: ±2A DC
DC BIAS VOLTAGE UNIT 9268
42 Hz to 5 MHz, Max. allowable voltage: ± 40 V DC
CONNECTION CORD 9166
Metal BNC to clip, 1.5 m (4.92 ft) length
TEST FIXTURE 9261
DC to 8 MHz, 1 m (3.28 ft) length, impedance characteristics of 75 Ω
4-TERMINAL PROBE 9140
DC to 100 kHz, 1 m (3.28 ft) length, impedance characteristics of 75 Ω
PINCHER PROBE L2001
Cable length 73 cm (2.40 ft), DC to 8 MHz, impedance characteristics of 50 Ω, 4-terminal pair configuration, tip electrode spacing: 0.3 (0.01 in) to 6 mm (0.24 in)
CONTACT TIPS IM9902
To replace the tip on the L2001, small size
CONTACT TIPS IM9901
To replace the tip on the L2001, regular size, bundled with the L2001
SMD TEST FIXTURE 9699
Direct connection type, For measuring SMDs with electrodes on the bottom; DC to 120 MHz, test sample dimensions: 1.0 mm (0.04 in) to 4.0 mm (0.16 in) wide, max. 1.5 mm (0.06 in) high
SMD TEST FIXTURE 9677
Direct connection type, For measuring SMDs with electrodes on the side; DC to 120 MHz, test sample dimensions: 3.5 mm ±0.5 mm (0.14 in ±0.02 in)
SMD TEST FIXTURE 9263
Direct connection type, DC to 8 MHz, Test sample dimensions:1 mm (0.04 in) to 10 mm (0.39 in)
TEST FIXTURE 9262
Direct connection type, DC to 8 MHz, measurable conductor diameter: ø0.3 (0.01 in) to 2 mm (0.08 in)
SMD TEST FIXTURE IM9100
• Direct connection type • SMDs with electrodes on the bottom • DC to 8MHz • Measurable sample sizes: 01005 to 0402 (EIA)