Dual-band 1kHz/1MHz Capacitance Meter for High Speed Testing of Ceramic Capacitors on Production Lines
DESCRIPTION
MODEL NO. (ORDER CODE)
3506-10 |
---|
Note: This product is not supplied with measurement probes or test fixtures. Please select and purchase the measurement probe or test fixture options appropriate for your application separately. For an RS-232C connection: A crossover cable for interconnection can be used. You can use the RS-232C cable 9637 without hardware flow control.
Hioki LCR Meters and Impedance Analyzers range from 1mHz to 3GHz devices to suit a wide range of applications in the testing of electronic components. The 3506-10 is a dual-band capacitance meter designed to be integrated with automatic taping machines and sorters for production of MLCC (multi-layer ceramic capacitors).
KEY FEATURES
• High-speed analog test time of 0.6 ms (at 1 MHz)
• Improved noise resistance and enhanced repeatability in measurement precision even for production lines
• 1 kHz and 1 MHz measurement frequency supports stable low capacitance testing with taping machines
• BIN function, for easy component screening
BASIC SPECIFICATIONS (ACCURACY GUARANTEED FOR 1 YEAR, POST-ADJUSTMENT ACCURACY GUARANTEED FOR 1 YEAR)
Measurement parameters | C (Capacitance), D (loss coefficient, tan δ), Q (1/tan δ) |
---|---|
Measurement range | C: 0.001 fF to 15.0000 μF, D: 0.00001 to 1.99999, Q: 0.0 to 19999.9 |
Basic accuracy | (Typ.) C: ±0.14 % rdg., D: ±0.0013 |
Measurement frequency | 1 kHz, 1 MHz |
Measurement signal level | 500 mV, 1 V rms |
Output impedance | 1 Ω (at 1 kHz in 2.2 μF and higher ranges), 20 Ω (in ranges other than the above) |
Display | LED (six digits, full scale count depends on measurement range) |
Measurement time | 1.5 ms: 1 MHz, 2.0 ms: 1 kHz |
Functions | BIN (measurement values can be classified by rank), Trigger-synchronous output, Setting configurations can be stored, Comparator, Averaging, Low-C reject (bad contact detection), Chatter detection, Current detection circuit monitoring, Applied voltage value monitoring, EXT. I/O, RS-232C, GP-IB |
Power supply | Selectable from 100, 120, 220 or 240 V AC ±10 %, 50/60 Hz 40 VA max. |
Dimensions and mass | 260 mm (10.24 in) W × 100 mm (3.94 in) H × 298 mm (11.73 in) D, 4.8 kg (169.3 oz) |
Accessories | Power cord × 1, Instruction manual × 1, Spare fuse × 1 |
CATALOGS
C METER 3506-10, C HITESTER 3504
SMD TEST FIXTURE IM9110
ELECTRONIC COMPONENT MEASUREMENT APPLICATIONS
USER GUIDES
LCR APPLICATION GUIDE
DECLARATION OF CONFORMITY
C METER 3506-10 [100KB]
OPTIONS
Connection Options
* L9217: for motor analysis input
CONNECTION CABLE 9444
9 pin – 9 pin straight, 1.5 m (4.92 ft) length
PC communication
*The 9151-02 is only for the RM3545-01
GP-IB CONNECTOR CABLE 9151-02
2 m (6.56 ft) length
Printer options
*PRINTER UNIT is a built-in option that must be specified upon order.
AC ADAPTER 9443-02
For the Printer 9442, EU type
PRINTER 9442
For printing numerical values 112 mm (4.41 in) paper width, not CE marked
RECORDING PAPER 1196
For the Printer 9442, 112 mm (4.41 in) × 25 m (82.03 ft), 10 rolls/set
Probe and Test fixtures
CONTACT TIPS IM9901
To replace the tip on the L2001, regular size, bundled with the L2001
SMD TEST FIXTURE IM9110
• Direct connection two-terminal measurement type • DC to 1 MHz • Measurable sample sizes: 008004 (EIA)
PINCHER PROBE L2001
Cable length 73 cm (2.40 ft), DC to 8 MHz, impedance characteristics of 50 Ω, 4-terminal pair configuration, tip electrode spacing: 0.3 (0.01 in) to 6 mm (0.24 in)
4-TERMINAL PROBE L2000
Cable length 1 m (3.28 ft), DC to 8 MHz, impedance characteristics of 50 Ω, 4-terminal pair configuration, measurable conductor diameter: ø0.3 (0.01 in) to 5 mm (0.20 in)
CONTACT TIPS IM9902
To replace the tip on the L2001, small size
SMD TEST FIXTURE 9699
Direct connection type, For measuring SMDs with electrodes on the bottom; DC to 120 MHz, test sample dimensions: 1.0 mm (0.04 in) to 4.0 mm (0.16 in) wide, max. 1.5 mm (0.06 in) high
SMD TEST FIXTURE 9677
Direct connection type, For measuring SMDs with electrodes on the side; DC to 120 MHz, test sample dimensions: 3.5 mm ±0.5 mm (0.14 in ±0.02 in)
4-TERMINAL PROBE 9500-10
Cable length 1 m (3.28 ft), DC to 200 kHz, impedance characteristics of 50 Ω, measurable conductor diameter: φ0.3 mm (0.01 in) to 2 mm (0.08 in)
SMD TEST FIXTURE 9263
Direct connection type, DC to 8 MHz, Test sample dimensions:1 mm (0.04 in) to 10 mm (0.39 in)
TEST FIXTURE 9262
Direct connection type, DC to 8 MHz, measurable conductor diameter: ø0.3 (0.01 in) to 2 mm (0.08 in)
TEST FIXTURE 9261-10
Cable length 1 m (3.28 ft), DC to 8 MHz, impedance characteristics of 50 Ω, 4-terminal pair configuration, measurable conductor diameter: ø0.3 (0.01 in) to 1.5 mm (0.06 in)
4-TERMINAL PROBE 9140-10
Cable length 1 m (3.28 ft), DC to 200 kHz, impedance characteristics of 50 Ω, 4-terminal pair configuration, measurable conductor diameter: ø0.3 (0.01 in) to 5 mm (0.20 in)
SMD TEST FIXTURE IM9100
• Direct connection type • SMDs with electrodes on the bottom • DC to 8MHz • Measurable sample sizes: 01005 to 0402 (EIA)