SYMPHONIE® IPACKACCESS | LTE-G

SYMPHONIE® IPACKACCESS | LTE-G

SYMPHONIE® IPACKACCESS | LTE-G

Integrate real-time meteorological data into your SCADA system with the iPackACCESS communications module.

DETAILS

iPackACCESS is a communications and power module for the SymphoniePRO®  data loggers that enables wind farm operators to integrate real-time meteorological data into their SCADA (Supervisory Control and Data Acquisition) systems via Modbus TCP or LTE-G cellular network.

iPackACCESS serves up real-time 1 Hz sample as well as statistical data at user-selected intervals. Data are delivered to pre-defined Modbus registers or via email by cellular modem. With no coding required, iPackACCESS offers ease-of-use and data security by limiting access to defined IP addresses.

DATA LOGGER CONNECTION

iPackACCESS attaches to a port located on the back of your Symphonie series data logger. The iPackACCESS and data logger are then mounted in a Symphonie shelter box for security and environmental protection.

MODBUS DEMO CLIENT APPLICATION

This lightweight utility can be run off of a USB drive and used at various points in your network to troubleshoot and establish the proper connectivity of your logger/iPack system. The latest version is compatible with the SymphoniePRO data logger when paired with an iPackACCESS.

BENEFITS

  • Deliver real-time, 1 Hz meteorological data into your wind farm’s SCADA system via Modbus TCP or LTE-G cellular network.
  • Deliver statistical data (average, standard deviation, min, max, and max 3-sec gust*) at user-selected intervals (1, 2, 5, 10, 15, 30, and 60 minutes) so it can be directly forwarded to forecasting providers or other stakeholders*
  • Access the data on pre-defined registers using industry-standard Modbus TCP protocol or through LTE-G cellular network.*
  • Ensure the security of your data by limiting access via user-defined IP addresses
  • Quickly install the unit in the field, no coding required*

* Feature enhanced by and/or exclusively available when iPackACCESS is paired with SymphoniePRO.

IN THE BOX

  • One (1) Symphonie iPackACCESS
  • One (1) GPS antenna

Note: The iPack voltmeter SCM is now included in SymphoniePLUS3 data logger kits. SymphoniePRO includes built-in monitoring of the 12V power supply and does not require a separate interface module.

SPECIFICATIONS PRINT SPECS

 LTE-G AT&T (#16691)LTE-G WindLinx (#16693)
DESCRIPTION 
Accessory typeCommunications + power module for SymphoniePRO data loggersCommunications + power module for SymphoniePRO data loggers
ApplicationsDelivery of real-time (1 Hz sample) and statistical meteorological data for resource assessment, power performance testing, long-term monitoring, and/or forecastingDelivery of real-time (1 Hz sample) and statistical meteorological data for resource assessment, power performance testing, long-term monitoring, and/or forecasting
Instrument compatibilitySymphoniePRO data loggersSymphoniePRO data loggers
FunctionsDelivery of meteorological data via:Modbus TCP server, email, and/or MetLink* available over EthernetLTE-G cellular modem
Supports up to 4 simultaneous Modbus TCP/MetLink connectionsSupports remote configuration and firmware updates to data logger and iPackACCESS via MetLink*Automatic synchronization of data logger’s real-time clock via GPS and/or internet time (NTP) server*Automatic delivery of logged data via email
*Functionality available exclusively via Ethernet interface
Delivery of meteorological data via:Modbus TCP server, email, and/or MetLink* available over EthernetLTE-G cellular modem
Supports up to 4 simultaneous Modbus TCP/MetLink connectionsSupports remote configuration and firmware updates to data logger and iPackACCESS via MetLink*Automatic synchronization of data logger’s real-time clock via GPS and/or internet time (NTP) server*Automatic delivery of logged data via email
*Functionality available exclusively via Ethernet interface
DATA COLLECTION 
SoftwareConfiguration via data logger desktop software on Windows PC (SymphoniePRO Desktop Application (SPD))Configuration via data logger desktop software on Windows PC (SymphoniePRO Desktop Application (SPD))
Data deliveryData available via Modbus TCP server:Real-time, 1 Hz sample data from all channelsStatistical values at user-selected time interval configured in the data logger (1, 2, 5, 10, 15, 30, or 60 minutes)*
Raw logger data files available:by email and/or MetLink via Ethernet interface (SCADA network connection)by email only via cellular modemlocally via logger USB connection or SD card
Data available via Modbus TCP server:Real-time, 1 Hz sample data from all channelsStatistical values at user-selected time interval configured in the data logger (1, 2, 5, 10, 15, 30, or 60 minutes)*
Raw logger data files available:by email and/or MetLink via Ethernet interface (SCADA network connection)by email only via cellular modemlocally via logger USB connection or SD card
CONFIGURATION 
User interfaceStatus reporting via data logger user interfaceConfiguration via data logger desktop software on Windows PC (SymphoniePRO Desktop Application (SPD))Status reporting via data logger user interfaceConfiguration via data logger desktop software on Windows PC (SymphoniePRO Desktop Application (SPD))
Configurable parametersModbus secure client list to prevent unauthorized access by limiting the acceptable IP addresses for incoming connections (up to 10 allowable addresses)Network configuration parametersDHCP capableModbus secure client list to prevent unauthorized access by limiting the acceptable IP addresses for incoming connections (up to 10 allowable addresses)Network configuration parametersDHCP capable
CONNECTIONS 
Communication portsWeatherproof Ethernet connector (RJ45) for connection to SCADA systemDB25 connector for interface to data loggerQMA (f) connector for GPS antennaSMA (f) connector for cellular antennaWeatherproof Ethernet connector (RJ45) for connection to SCADA systemDB25 connector for interface to data loggerQMA (f) connector for GPS antennaSMA (f) connector for cellular antenna
POWER REQUIREMENTS 
BatteriesTwo (2) built-in 12 V Sealed Lead-Acid (SLA) batteries with 2200 mAh rating each (4400 mAh total)Two (2) built-in 12 V Sealed Lead-Acid (SLA) batteries with 2200 mAh rating each (4400 mAh total)
External power inputExternal battery input (12 to 14 V, 500 mA max.)External battery input (12 to 14 V, 500 mA max.)
External solar input12 V (nominal) solar PV panel or external power supply (15 to 28 V), 1 A max.12 V (nominal) solar PV panel or external power supply (15 to 28 V), 1 A max.
External power outputSmart-switched 12 V DC output from internal SLA batteries (~4400 mAh)Smart-switched 12 V DC output from internal SLA batteries (~4400 mAh)
INSTALLATION 
MountingiPackACCESS attaches to back of SymphoniePRO data logger with (4) long logger mounting screwsiPackACCESS attaches to back of SymphoniePRO data logger with (4) long logger mounting screws
AccessoriesWeatherproof Ethernet cable boot, GPS antenna, and cellular antenna (included)Weatherproof Ethernet cable boot, GPS antenna, and cellular antenna (included)
PHYSICAL 
ConnectionsTwo (2) screw terminals for solar PV panel or external power supply inputTwo (2) screw terminals for external batteryTwo (2) screw terminals for 12 V power outputOne (1) screw terminal for earth ground, pre-wired for connection to data logger earth ground studTwo (2) screw terminals for solar PV panel or external power supply inputTwo (2) screw terminals for external batteryTwo (2) screw terminals for 12 V power outputOne (1) screw terminal for earth ground, pre-wired for connection to data logger earth ground stud
Dimensions165 x 222 x 102 mm (6.5 x 8.75 x 4.0 inches)165 x 222 x 102 mm (6.5 x 8.75 x 4.0 inches)
MATERIALS 
EnclosureWeather-proof polycarbonate plasticIP65 RatedWeather-proof polycarbonate plasticIP65 Rated
SYSTEM REQUIREMENTS 
ComputerWindows PC with SymphoniePRO Desktop Application (SPD) required for configurationModbus Demo Client software utility for network connection testing and troubleshootingWindows PC with SymphoniePRO Desktop Application (SPD) required for configurationModbus Demo Client software utility for network connection testing and troubleshooting
Operating systemSymphoniePRO Desktop Application requires Windows 7 or higherSymphoniePRO Desktop Application requires Windows 7 or higher
Related hardwareSymphoniePRO Data Logger (item 8547)USB Cable | 15 FT, A to B Type (item 8633)Universal iPack Charger (item 3615)SymphoniePRO Data Logger (item 8547)USB Cable | 15 FT, A to B Type (item 8633)Universal iPack Charger (item 3615)