Integrate real-time meteorological data into your SCADA system with the iPackACCESS communications module.
DETAILS
iPackACCESS is a communications and power module for the SymphoniePRO® data loggers that enables wind farm operators to integrate real-time meteorological data into their SCADA (Supervisory Control and Data Acquisition) systems via Modbus TCP or LTE-G cellular network.
iPackACCESS serves up real-time 1 Hz sample as well as statistical data at user-selected intervals. Data are delivered to pre-defined Modbus registers or via email by cellular modem. With no coding required, iPackACCESS offers ease-of-use and data security by limiting access to defined IP addresses.
DATA LOGGER CONNECTION
iPackACCESS attaches to a port located on the back of your Symphonie series data logger. The iPackACCESS and data logger are then mounted in a Symphonie shelter box for security and environmental protection.
MODBUS DEMO CLIENT APPLICATION
This lightweight utility can be run off of a USB drive and used at various points in your network to troubleshoot and establish the proper connectivity of your logger/iPack system. The latest version is compatible with the SymphoniePRO data logger when paired with an iPackACCESS.
BENEFITS
- Deliver real-time, 1 Hz meteorological data into your wind farm’s SCADA system via Modbus TCP or LTE-G cellular network.
- Deliver statistical data (average, standard deviation, min, max, and max 3-sec gust*) at user-selected intervals (1, 2, 5, 10, 15, 30, and 60 minutes) so it can be directly forwarded to forecasting providers or other stakeholders*
- Access the data on pre-defined registers using industry-standard Modbus TCP protocol or through LTE-G cellular network.*
- Ensure the security of your data by limiting access via user-defined IP addresses
- Quickly install the unit in the field, no coding required*
* Feature enhanced by and/or exclusively available when iPackACCESS is paired with SymphoniePRO.
IN THE BOX
- One (1) Symphonie iPackACCESS
- One (1) GPS antenna
Note: The iPack voltmeter SCM is now included in SymphoniePLUS3 data logger kits. SymphoniePRO includes built-in monitoring of the 12V power supply and does not require a separate interface module.
SPECIFICATIONS PRINT SPECS
LTE-G AT&T (#16691) | LTE-G WindLinx (#16693) | |
---|---|---|
DESCRIPTION | ||
Accessory type | Communications + power module for SymphoniePRO data loggers | Communications + power module for SymphoniePRO data loggers |
Applications | Delivery of real-time (1 Hz sample) and statistical meteorological data for resource assessment, power performance testing, long-term monitoring, and/or forecasting | Delivery of real-time (1 Hz sample) and statistical meteorological data for resource assessment, power performance testing, long-term monitoring, and/or forecasting |
Instrument compatibility | SymphoniePRO data loggers | SymphoniePRO data loggers |
Functions | Delivery of meteorological data via:Modbus TCP server, email, and/or MetLink* available over EthernetLTE-G cellular modem Supports up to 4 simultaneous Modbus TCP/MetLink connectionsSupports remote configuration and firmware updates to data logger and iPackACCESS via MetLink*Automatic synchronization of data logger’s real-time clock via GPS and/or internet time (NTP) server*Automatic delivery of logged data via email *Functionality available exclusively via Ethernet interface | Delivery of meteorological data via:Modbus TCP server, email, and/or MetLink* available over EthernetLTE-G cellular modem Supports up to 4 simultaneous Modbus TCP/MetLink connectionsSupports remote configuration and firmware updates to data logger and iPackACCESS via MetLink*Automatic synchronization of data logger’s real-time clock via GPS and/or internet time (NTP) server*Automatic delivery of logged data via email *Functionality available exclusively via Ethernet interface |
DATA COLLECTION | ||
Software | Configuration via data logger desktop software on Windows PC (SymphoniePRO Desktop Application (SPD)) | Configuration via data logger desktop software on Windows PC (SymphoniePRO Desktop Application (SPD)) |
Data delivery | Data available via Modbus TCP server:Real-time, 1 Hz sample data from all channelsStatistical values at user-selected time interval configured in the data logger (1, 2, 5, 10, 15, 30, or 60 minutes)* Raw logger data files available:by email and/or MetLink via Ethernet interface (SCADA network connection)by email only via cellular modemlocally via logger USB connection or SD card | Data available via Modbus TCP server:Real-time, 1 Hz sample data from all channelsStatistical values at user-selected time interval configured in the data logger (1, 2, 5, 10, 15, 30, or 60 minutes)* Raw logger data files available:by email and/or MetLink via Ethernet interface (SCADA network connection)by email only via cellular modemlocally via logger USB connection or SD card |
CONFIGURATION | ||
User interface | Status reporting via data logger user interfaceConfiguration via data logger desktop software on Windows PC (SymphoniePRO Desktop Application (SPD)) | Status reporting via data logger user interfaceConfiguration via data logger desktop software on Windows PC (SymphoniePRO Desktop Application (SPD)) |
Configurable parameters | Modbus secure client list to prevent unauthorized access by limiting the acceptable IP addresses for incoming connections (up to 10 allowable addresses)Network configuration parametersDHCP capable | Modbus secure client list to prevent unauthorized access by limiting the acceptable IP addresses for incoming connections (up to 10 allowable addresses)Network configuration parametersDHCP capable |
CONNECTIONS | ||
Communication ports | Weatherproof Ethernet connector (RJ45) for connection to SCADA systemDB25 connector for interface to data loggerQMA (f) connector for GPS antennaSMA (f) connector for cellular antenna | Weatherproof Ethernet connector (RJ45) for connection to SCADA systemDB25 connector for interface to data loggerQMA (f) connector for GPS antennaSMA (f) connector for cellular antenna |
POWER REQUIREMENTS | ||
Batteries | Two (2) built-in 12 V Sealed Lead-Acid (SLA) batteries with 2200 mAh rating each (4400 mAh total) | Two (2) built-in 12 V Sealed Lead-Acid (SLA) batteries with 2200 mAh rating each (4400 mAh total) |
External power input | External battery input (12 to 14 V, 500 mA max.) | External battery input (12 to 14 V, 500 mA max.) |
External solar input | 12 V (nominal) solar PV panel or external power supply (15 to 28 V), 1 A max. | 12 V (nominal) solar PV panel or external power supply (15 to 28 V), 1 A max. |
External power output | Smart-switched 12 V DC output from internal SLA batteries (~4400 mAh) | Smart-switched 12 V DC output from internal SLA batteries (~4400 mAh) |
INSTALLATION | ||
Mounting | iPackACCESS attaches to back of SymphoniePRO data logger with (4) long logger mounting screws | iPackACCESS attaches to back of SymphoniePRO data logger with (4) long logger mounting screws |
Accessories | Weatherproof Ethernet cable boot, GPS antenna, and cellular antenna (included) | Weatherproof Ethernet cable boot, GPS antenna, and cellular antenna (included) |
PHYSICAL | ||
Connections | Two (2) screw terminals for solar PV panel or external power supply inputTwo (2) screw terminals for external batteryTwo (2) screw terminals for 12 V power outputOne (1) screw terminal for earth ground, pre-wired for connection to data logger earth ground stud | Two (2) screw terminals for solar PV panel or external power supply inputTwo (2) screw terminals for external batteryTwo (2) screw terminals for 12 V power outputOne (1) screw terminal for earth ground, pre-wired for connection to data logger earth ground stud |
Dimensions | 165 x 222 x 102 mm (6.5 x 8.75 x 4.0 inches) | 165 x 222 x 102 mm (6.5 x 8.75 x 4.0 inches) |
MATERIALS | ||
Enclosure | Weather-proof polycarbonate plasticIP65 Rated | Weather-proof polycarbonate plasticIP65 Rated |
SYSTEM REQUIREMENTS | ||
Computer | Windows PC with SymphoniePRO Desktop Application (SPD) required for configurationModbus Demo Client software utility for network connection testing and troubleshooting | Windows PC with SymphoniePRO Desktop Application (SPD) required for configurationModbus Demo Client software utility for network connection testing and troubleshooting |
Operating system | SymphoniePRO Desktop Application requires Windows 7 or higher | SymphoniePRO Desktop Application requires Windows 7 or higher |
Related hardware | SymphoniePRO Data Logger (item 8547)USB Cable | 15 FT, A to B Type (item 8633)Universal iPack Charger (item 3615) | SymphoniePRO Data Logger (item 8547)USB Cable | 15 FT, A to B Type (item 8633)Universal iPack Charger (item 3615) |