THIES FIRST CLASS ADVANCED ANEMOMETER

THIES FIRST CLASS ADVANCED ANEMOMETER

THIES FIRST CLASS ADVANCED ANEMOMETER

The Thies First Class Advanced (FCA) Anemometer is a class 1 anemometer that delivers high-end performance in any terrain.

DETAILS

The Thies FCA Anemometer is ideally suited for wind resource assessment and power performance studies at IEC 61400-12-1 Class A and B sites.

The Thies FCA Anemometer comes with a MEASNET calibration certificate, and it is compatible with all Symphonie series data loggers. You will need to use Signal Conditioning Modules (SCM #3151) when connecting more than six anemometers to a SymphoniePLUS®3 Data Logger, but no interface module is required when connecting to a SymphoniePRO® Data Logger – Wind. These sensors can also be integrated seamlessly with our .

Use the Thies Adapter boom extension (#9344) to mount Thies First Class Advanced Anemometers on any 25 mm (.98”) diameter vertical pipe, such as NRG boom #4478 or any boom already fitted with a WindSensor Adapter Kit.

BENEFITS

  • Class 0.5 anemometer
  • Optimised dynamic behavior even at high turbulence intensity
  • Minimum over-speeding
  • Excellent linearity: r > .99999
  • Low power consumption
  • High Survival Speed
  • Symmetrical geometry
  • MEASNET Calibrated

SPECIFICATIONS PRINT SPECS

 MEASNET Calibrated (#9288)
DESCRIPTION 
Sensor type3-cup anemometer, model 4.3351.10.000
ApplicationsWind resource assessmentMeteorological studiesEnvironmental monitoring
Sensor range0.3 m/s to 75 m/s (0.7 mph to 168 mph)
Instrument compatibilityAll NRG Data Loggers
OUTPUT SIGNAL 
Signal typeForm: Square Wave
Frequency: 1082 Hz @ 50 m/s (112 mph)
Amplitude: Equal to supply voltage, max. 15 V
Anemometer Transfer FunctionRefer to individual calibration report for sensor-specific transfer function.
Typical transfer function between frequency and wind speed:y = 0.0462f + 0.21
Recommended load resistanceR > 1 kΩ (Push-pull output with 220 Ω in series)
C < nF (corresponds to typical cable length < 1 km)
CalibrationEach anemometer individually calibrated, calibration reports provided via electronic downloadNonlinearity < 1%
Resolution0.05 m wind run
UncertaintyIEC 61400-12-1 ClassificationClass 0.9AClass 3.0BClass 0.5S
RESPONSE CHARACTERISTICS 
Threshold< 0.3 m/s (0.7 mph)
Distance constant (63% recovery)< 3m (9.8ft) (according to ASTM D 5096 – 96)
Moment of inertia3.41 x 10-4 kg-m2
POWER REQUIREMENTS 
Supply voltage3.3 VDC to 42 VDC (galvanic isolation from housing)
Supply current0.3 mA @ 3.3 V typical (w/o external load)
(Less than 0.5 mA @ 5 V (w/o external load))
INSTALLATION 
MountingOnto a 35 mm (1.38 inch) diameter mast with two set screws
Tools required3 mm Allen wrench
ENVIRONMENTAL 
Operating temperature range-50 °C to 80 °C (-58 °F to 176 °F)
Operating humidity range0 to 100% RHIncluding dew moistening
PHYSICAL 
Connections8 pole plug-connection for shielded cable
Weight0.5 kg (1.1 lbs)
Dimensions3 cups of conical cross-section240 mm (9.45″) rotor dia.290 mm (11.42″) overall height
MATERIALS 
CupsCarbon-fiber reinforced plastic
BodyAnodized aluminum
ShaftAnodized aluminum
BearingStainless steel ball bearing

Categories

Social Links