The Thies First Class Advanced (FCA) Anemometer is a class 1 anemometer that delivers high-end performance in any terrain.
DETAILS
The Thies FCA Anemometer is ideally suited for wind resource assessment and power performance studies at IEC 61400-12-1 Class A and B sites.
The Thies FCA Anemometer comes with a MEASNET calibration certificate, and it is compatible with all Symphonie series data loggers. You will need to use Signal Conditioning Modules (SCM #3151) when connecting more than six anemometers to a SymphoniePLUS®3 Data Logger, but no interface module is required when connecting to a SymphoniePRO® Data Logger – Wind. These sensors can also be integrated seamlessly with our .
Use the Thies Adapter boom extension (#9344) to mount Thies First Class Advanced Anemometers on any 25 mm (.98”) diameter vertical pipe, such as NRG boom #4478 or any boom already fitted with a WindSensor Adapter Kit.
BENEFITS
- Class 0.5 anemometer
- Optimised dynamic behavior even at high turbulence intensity
- Minimum over-speeding
- Excellent linearity: r > .99999
- Low power consumption
- High Survival Speed
- Symmetrical geometry
- MEASNET Calibrated
SPECIFICATIONS PRINT SPECS
MEASNET Calibrated (#9288) | |
---|---|
DESCRIPTION | |
Sensor type | 3-cup anemometer, model 4.3351.10.000 |
Applications | Wind resource assessmentMeteorological studiesEnvironmental monitoring |
Sensor range | 0.3 m/s to 75 m/s (0.7 mph to 168 mph) |
Instrument compatibility | All NRG Data Loggers |
OUTPUT SIGNAL | |
Signal type | Form: Square Wave Frequency: 1082 Hz @ 50 m/s (112 mph) Amplitude: Equal to supply voltage, max. 15 V |
Anemometer Transfer Function | Refer to individual calibration report for sensor-specific transfer function. Typical transfer function between frequency and wind speed:y = 0.0462f + 0.21 |
Recommended load resistance | R > 1 kΩ (Push-pull output with 220 Ω in series) C < nF (corresponds to typical cable length < 1 km) |
Calibration | Each anemometer individually calibrated, calibration reports provided via electronic downloadNonlinearity < 1% |
Resolution | 0.05 m wind run |
Uncertainty | IEC 61400-12-1 ClassificationClass 0.9AClass 3.0BClass 0.5S |
RESPONSE CHARACTERISTICS | |
Threshold | < 0.3 m/s (0.7 mph) |
Distance constant (63% recovery) | < 3m (9.8ft) (according to ASTM D 5096 – 96) |
Moment of inertia | 3.41 x 10-4 kg-m2 |
POWER REQUIREMENTS | |
Supply voltage | 3.3 VDC to 42 VDC (galvanic isolation from housing) |
Supply current | 0.3 mA @ 3.3 V typical (w/o external load) (Less than 0.5 mA @ 5 V (w/o external load)) |
INSTALLATION | |
Mounting | Onto a 35 mm (1.38 inch) diameter mast with two set screws |
Tools required | 3 mm Allen wrench |
ENVIRONMENTAL | |
Operating temperature range | -50 °C to 80 °C (-58 °F to 176 °F) |
Operating humidity range | 0 to 100% RHIncluding dew moistening |
PHYSICAL | |
Connections | 8 pole plug-connection for shielded cable |
Weight | 0.5 kg (1.1 lbs) |
Dimensions | 3 cups of conical cross-section240 mm (9.45″) rotor dia.290 mm (11.42″) overall height |
MATERIALS | |
Cups | Carbon-fiber reinforced plastic |
Body | Anodized aluminum |
Shaft | Anodized aluminum |
Bearing | Stainless steel ball bearing |