This next generation ambient temperature sensor builds on the NRG 110S’s trusted design, offering improved temperature accuracy and long-term reliability in harsh environments.
DETAILS
The NRG T60 Temperature Sensor brings a new sensing element to the NRG 110S’s time-tested form. The result is a durable, reliable sensor that offers reduced measurement uncertainty and is capable of capturing measurements at higher temperatures. Because the T60 maintains the same physical design, signal output, and wiring scheme as the 110S, transitioning to this next generation sensor is exceptionally easy.
The T60 is ideally suited for the temperature measurement requirements of remote wind and solar energy studies. Recommended uses of the data from this sensor include calculating energy density calculations; monitoring air temperature; calculating atmospheric stability conditions; identifying icing conditions in cold climates; and estimating PV panel efficiency, which is temperature dependent.
*Please note: T60C is the calibrated version of this sensor.
BENEFITS
- Lower measurement uncertainty
- ILAC-compliant, NIST-traceable calibrations available from an ISO 9001:2008, ISO/IEC 17025:2017 certified laboratory
- Can measure up to 70°C (5°C greater than the 110S)
- Suitable for the temperature measurement requirements of remote wind and solar energy studies
- Same physical design, body materials, and radiation shield as the 110S, ensuring seamless transition to T60
SPECIFICATIONS PRINT SPECS
4.6m cable (#9400) | 13m cable (#9411) | 67m cable (#9402) | 90m cable (#9403) | 110m cable (#9404) | 13m Cable – Calibrated (#9401) | |
---|---|---|---|---|---|---|
DESCRIPTION | ||||||
Sensor type | Integrated circuit ambient temperature sensor with six plate radiation shield | Integrated circuit ambient temperature sensor with six plate radiation shield | Integrated circuit ambient temperature sensor with six plate radiation shield | Integrated circuit ambient temperature sensor with six plate radiation shield | Integrated circuit ambient temperature sensor with six plate radiation shield | Integrated circuit ambient temperature sensor with six plate radiation shield |
Applications | Wind and solar resource assessmentWind and solar plant operationsMeteorological studiesEnvironmental monitoring | Wind and solar resource assessmentWind and solar plant operationsMeteorological studiesEnvironmental monitoring | Wind and solar resource assessmentWind and solar plant operationsMeteorological studiesEnvironmental monitoring | Wind and solar resource assessmentWind and solar plant operationsMeteorological studiesEnvironmental monitoring | Wind and solar resource assessmentWind and solar plant operationsMeteorological studiesEnvironmental monitoring | Wind and solar resource assessmentWind and solar plant operationsMeteorological studiesEnvironmental monitoring |
Sensor range | -40 °C to 70 °C (-40 °F to 158 °F) | -40 °C to 70 °C (-40 °F to 158 °F) | -40 °C to 70 °C (-40 °F to 158 °F) | -40 °C to 70 °C (-40 °F to 158 °F) | -40 °C to 70 °C (-40 °F to 158 °F) | -40 °C to 70 °C (-40 °F to 158 °F) |
Instrument compatibility | All NRG loggers | All NRG loggers | All NRG loggers | All NRG loggers | All NRG loggers | All NRG loggers |
OUTPUT SIGNAL | ||||||
Signal type | Linear analog voltage | Linear analog voltage | Linear analog voltage | Linear analog voltage | Linear analog voltage | Linear analog voltage |
Transfer function | Temperature (°C) = (Voltage x 44.74364) -40.85555 °C Temperature (°F) = (Voltage x 80.53855) -41.53999 °F | Temperature (°C) = (Voltage x 44.74364) – 40.85555 °C Temperature (°F) = (Voltage x 80.53855) – 41.53999 °F Note: Transfer function above applies to 4.6-meter cable. For sensors with cable lengths longer than 4.6 meters, subtract 0.002922 °C (0.0052596 °F) per additional meter from the transfer function offset. | Temperature (°C) = (Voltage x 44.74364) – 40.85555 °C Temperature (°F) = (Voltage x 80.53855) – 41.53999 °F Note: Transfer function above applies to 4.6-meter cable. For sensors with cable lengths longer than 4.6 meters, subtract 0.002922 °C (0.0052596 °F) per additional meter from the transfer function offset. | Temperature (°C) = (Voltage x 44.74364) – 40.85555 °C Temperature (°F) = (Voltage x 80.53855) – 41.53999 °F Note: Transfer function above applies to 4.6-meter cable. For sensors with cable lengths longer than 4.6 meters, subtract 0.002922 °C (0.0052596 °F) per additional meter from the transfer function offset. | Temperature (°C) = (Voltage x 44.74364) – 40.85555 °C Temperature (°F) = (Voltage x 80.53855) – 41.53999 °F Note: Transfer function above applies to 4.6-meter cable. For sensors with cable lengths longer than 4.6 meters, subtract 0.002922 °C (0.0052596 °F) per additional meter from the transfer function offset. | Please refer to your calibration report. |
Accuracy | Uncertainty (k=2): ±0.200 °C (±0.360 °F) | Uncertainty (k=2): ±0.200 °C (±0.360 °F) | Uncertainty (k=2): ±0.200 °C (±0.360 °F) | Uncertainty (k=2): ±0.200 °C (±0.360 °F) | Uncertainty (k=2): ±0.200 °C (±0.360 °F) | Uncertainty (k=2): ±0.200 °C (±0.360 °F) |
Output signal range | 0.020 to 2.480 V DC | 0.020 to 2.480 V DC | 0.020 to 2.480 V DC | 0.020 to 2.480 V DC | 0.020 to 2.480 V DC | 0.020 to 2.480 V DC |
Turn on time | <20 ms | <20 ms | <20 ms | <20 ms | <20 ms | <20 ms |
Resolution | 0.0025 °C (0.0045 °F) | 0.0025 °C (0.0045 °F) | 0.0025 °C (0.0045 °F) | 0.0025 °C (0.0045 °F) | 0.0025 °C (0.0045 °F) | 0.0025 °C (0.0045 °F) |
RESPONSE CHARACTERISTICS | ||||||
Thermal time constant | 5.38 minutes | 5.38 minutes | 5.38 minutes | 5.38 minutes | 5.38 minutes | 5.38 minutes |
POWER REQUIREMENTS | ||||||
Supply voltage | 5 to 15 V DC 5 V pulsed excitation strongly recommended | 5 to 15 V DC 5 V pulsed excitation strongly recommended | 5 to 15 V DC 5 V pulsed excitation strongly recommended | 5 to 15 V DC 5 V pulsed excitation strongly recommended | 5 to 15 V DC 5 V pulsed excitation strongly recommended | 5 to 15 V DC 5 V pulsed excitation strongly recommended |
Supply current | 1.2 mA max. (no load on output)SymphoniePRO Pulsed: 0.85 mA averageSymphoniePLUS3 Pulsed: 0.43 mA average | 1.2 mA max. (no load on output)SymphoniePRO Pulsed: 0.85 mA averageSymphoniePLUS3 Pulsed: 0.43 mA average | 1.2 mA max. (no load on output)SymphoniePRO Pulsed: 0.85 mA averageSymphoniePLUS3 Pulsed: 0.43 mA average | 1.2 mA max. (no load on output)SymphoniePRO Pulsed: 0.85 mA averageSymphoniePLUS3 Pulsed: 0.43 mA average | 1.2 mA max. (no load on output)SymphoniePRO Pulsed: 0.85 mA averageSymphoniePLUS3 Pulsed: 0.43 mA average | 1.2 mA max. (no load on output)SymphoniePRO Pulsed: 0.85 mA averageSymphoniePLUS3 Pulsed: 0.43 mA average |
INSTALLATION | ||||||
Mounting | Attaches to tower with included hose clamps | Attaches to tower with included hose clamps | Attaches to tower with included hose clamps | Attaches to tower with included hose clamps | Attaches to tower with included hose clamps | Attaches to tower with included hose clamps |
Tools required | 8 mm (5/16 inch) nut driver or flat blade (-) screwdriver (to install hose clamps)Sheet metal shears or similar (for trimming hose clamps) | 8 mm (5/16 inch) nut driver or flat blade (-) screwdriver (to install hose clamps)Sheet metal shears or similar (for trimming hose clamps) | 8 mm (5/16 inch) nut driver or flat blade (-) screwdriver (to install hose clamps)Sheet metal shears or similar (for trimming hose clamps) | 8 mm (5/16 inch) nut driver or flat blade (-) screwdriver (to install hose clamps)Sheet metal shears or similar (for trimming hose clamps) | 8 mm (5/16 inch) nut driver or flat blade (-) screwdriver (to install hose clamps)Sheet metal shears or similar (for trimming hose clamps) | 8 mm (5/16 inch) nut driver or flat blade (-) screwdriver (to install hose clamps)Sheet metal shears or similar (for trimming hose clamps) |
ENVIRONMENTAL | ||||||
Operating temperature range | -40 °C to 70 °C (-40 °F to 158 °F) | -40 °C to 70 °C (-40 °F to 158 °F) | -40 °C to 70 °C (-40 °F to 158 °F) | -40 °C to 70 °C (-40 °F to 158 °F) | -40 °C to 70 °C (-40 °F to 158 °F) | -40 °C to 70 °C (-40 °F to 158 °F) |
Operating humidity range | 0 to 100% RH | 0 to 100% RH | 0 to 100% RH | 0 to 100% RH | 0 to 100% RH | 0 to 100% RH |
Lifespan | 10 years + | 10 years + | 10 years + | 10 years + | 10 years + | 10 years + |
Other | IPX7 Rated | IPX7 Rated | IPX7 Rated | IPX7 Rated | IPX7 Rated | IPX7 Rated |
PHYSICAL | ||||||
Connections | Wire leads:Signal (clear wire)Ground (black wire)Excitation (red wire)Shield wire for earth ground | Wire leads:Signal (clear wire)Ground (black wire)Excitation (red wire)Shield wire for earth ground | Wire leads:Signal (clear wire)Ground (black wire)Excitation (red wire)Shield wire for earth ground | Wire leads:Signal (clear wire)Ground (black wire)Excitation (red wire)Shield wire for earth ground | Wire leads:Signal (clear wire)Ground (black wire)Excitation (red wire)Shield wire for earth ground | Wire leads:Signal (clear wire)Ground (black wire)Excitation (red wire)Shield wire for earth ground |
Cable length | 4.6 m (15 ft) | 13 m (42 ft) | 67 m (220 ft) | 90 m (295 ft) | 110 m (361 ft) | 13 m (42 ft) |
Weight | 0.47 kg (1.04 lbs) | 0.75 kg (1.65 lbs) | 2.53 kg (5.6 lbs) | 3.29 kg (7.2 lbs) | 3.94 kg (8.7 lbs) | 0.75 kg (1.65 lbs) |
Dimensions | Probe only: 51.6 mm (2″) height x 12.7 mm (0.5″) diameterRadiation shield: 124 mm (4.9″) height x 127 mm (5 inches) diameter | Probe only: 51.6 mm (2″) height x 12.7 mm (0.5″) diameterRadiation shield: 124 mm (4.9″) height x 127 mm (5 inches) diameter | Probe only: 51.6 mm (2″) height x 12.7 mm (0.5″) diameterRadiation shield: 124 mm (4.9″) height x 127 mm (5 inches) diameter | Probe only: 51.6 mm (2″) height x 12.7 mm (0.5″) diameterRadiation shield: 124 mm (4.9″) height x 127 mm (5 inches) diameter | Probe only: 51.6 mm (2″) height x 12.7 mm (0.5″) diameterRadiation shield: 124 mm (4.9″) height x 127 mm (5 inches) diameter | Probe only: 51.6 mm (2″) height x 12.7 mm (0.5″) diameterRadiation shield: 124 mm (4.9″) height x 127 mm (5 inches) diameter |
MATERIALS | ||||||
Cable | 3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket | 3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket | 3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket | 3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket | 3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket | 3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket |
Probe | Aluminum, epoxy filled | Aluminum, epoxy filled | Aluminum, epoxy filled | Aluminum, epoxy filled | Aluminum, epoxy filled | Aluminum, epoxy filled |
Shield | UV-stabilized thermoplastic solar radiation shield | UV-stabilized thermoplastic solar radiation shield | UV-stabilized thermoplastic solar radiation shield | UV-stabilized thermoplastic solar radiation shield | UV-stabilized thermoplastic solar radiation shield | UV-stabilized thermoplastic solar radiation shield |