1000V Direct Input, Portable 16-channel Memory Recorder for Data Acquisition During Vehicle Testing with Direct CAN Bus Input
DESCRIPTION
MODEL NO. (ORDER CODE)
MR8875 | Max. 16 – 60ch, 32MW memory, main unit only |
---|
Note: *Cannot operate alone, You must install other options
Hioki Memory HiCorders are high-speed waveform monitoring and recording devices that can simultaneously measure multiple physical phenomena such as voltage, current, temperature, vibration, weight, acceleration and rotation due to complete isolation between channels and from each channel to the ground. The MR8875 data acquisition (DAQ) recorder accommodates plug-and-play input modules to meet applications such as onboard vehicle analysis, current consumption testing of portable devices, and measuring the voltage waveforms of superconducting materials and contacts.
HOW TO USE MEMORY HICORDERS: AS A MULTI-CHANNEL HIGH-SPEED DATA LOGGER
The Hioki MR8875 revolutionizes data logging by letting you record data to the SD Card in real-time in high speeds. Up to 3 full seconds of data logged in as fast as every 2μsec can be precisely captured, and when recording up to 50μsec of data, you can store up to 60 channels of signals, all in real-time into one single SD Card.
HOW TO USE MEMORY HICORDERS: MEASURING ACCELERATION USING A STRAIN UNIT
Abrupt fluctuations in acceleration can cause unacceptable motion errors in automobiles, transportation equipment and industrial robots. The Hioki MR8857 Memory HiCorder installed with the strain measurement module can greatly assist in helping you measure and analyze these unexpected acceleration fluctuations across 16 channels. Watch this video to learn how to connect distortion gauge acceleration sensors and make proper settings with the intuitive interface, as well as use the recorder’s scaling function to efficiently record waveforms.
PRODUCT VIDEO
Key Features
•1000V input and instantaneous DC or RMS waveform measurement with new Analog Unit MR8905
•Measure multiple channels simultaneously despite handheld portable design
•Max. 2 μsec high-speed simultaneous logging for all input channels
•Save directly to the SD Card in real time for uninterrupted long-term logging
•16-bit high-resolution measurement of voltage, temperature, distortion and CAN signals
•FFT calculation, waveform calculation functions for advanced analysis
•Intuitive touch screen for optimal operability
•Tough against vibrations and extreme temperatures, with strengthened body ideal for in-vehicle testing and road tests
•3 different power supplies
BASIC SPECIFICATIONS (ACCURACY GUARANTEED FOR 1 YEAR, POST-ADJUSTMENT ACCURACY GUARANTEED FOR 1 YEAR)
Number of input units | Up to 4 slots |
---|---|
Number of channels | Max. 16 analog channels (Max. 60 channels when using the MR8902) + standard 8 logic channels + 2 pulse channels Note: For analog units, channels are isolated from each other and from the MR8875’s GND. For CAN unit ports or standard logic terminals or standard pulse terminals, all channels have common GND. |
Measurement ranges (20 div full-scale) | 5 mV to 10 V/div , 11 ranges (when using the MR8901), 500 mV to 50 V/div , 7 ranges (when using the MR8905), resolution : 1/1250 of range |
Max. rated voltage | Between terminals: 150 V DC Between terminal to earth: 100 V AC, DC (when using the MR8901) |
Frequency characteristics | DC to 100 kHz (-3 dB, when using the MR8901) |
Time axis | 200 µs to 5 min/div, 21 ranges, sampling period: 1/100 of range, External sampling possible |
Max. sampling rate | [When using MR8901] 500 kS/s (2 μs period, all channels simultaneously) [When using MR8902] 10 ms (all input channels are scanned at high speed during every recording interval) [When using MR8903] 200 kS/s (5 μs period, all channels simultaneously) External sampling: 200 kS/s (5 μs period) |
Measurement functions | High-speed function (high speed recording), Real-time calculation between channels, FFT calculation, or other functions |
Storage memory capacity | Total 32 M-words (memory expansion: N/A, 8 MW each input unit) Note: 1 word = 2 bytes, therefore 32 Mega-words = 64 Mega-bytes. Note: Storage memory can be allocated depending on the number of channels used at each input unit |
Removable storage | SD card slot ×1, USB 2.0 memory |
Display | Touch-panel operation 8.4-inch SVGA-TFT color LCD (800 × 600 dots) |
Communication interfaces | LAN: 100BASE-TX (DHCP, DNS supported, FTP server/ client, WEB server, send E-mail, command control) USB: USB 2.0 compliant, series mini-B receptacle ×1 (setting / measure with communication command, or file transfer SD card to PC), series A receptacle ×2 (USB memory, USB mouse/ key-board) |
Power supply | 1) AC adapter Z1002: 100 to 240 V AC (50/60 Hz), 56 VA 2) Battery pack Z1003: 7.2 V DC, 36 VA, continuous operation time: 1 hour with back light ON (AC adapter has priority when used in combination with battery pack), Charges while installed in the MR8875, recharging time: 3 hours 3) External DC Power: 10 to 28 V DC, 56 VA, (please contact your HIOKI distributor for connection cord) |
Dimensions and mass | 298 mm (11.73 in)W × 224 mm (8.82 in)H × 84 mm (3.31 in)D, 2.4 kg (84.7 oz), (excluding input units and the Battery pack Z1003) Reference data: 3.47 kg/ 122.4 oz (including the MR8901 ×4 units and the Battery pack Z1003) |
Accessories | Instruction manual ×1, Measurement guide ×1, AC adapter Z1002 ×1, Protection sheet ×1, USB cable ×1, Shoulder strap ×1, Application disk (Wave viewer Wv, communication commands table, CAN Editor) ×1 |
LABVIEW AND MATLAB SUPPORT
Compatible models | LabVIEW | MATLAB script |
---|---|---|
MR8875 | Available | Available |
CATALOGS
DIFFERENTIAL PROBE P9000
MULTI-CHANNEL PORTABLE MEMORY RECORDER
NON-CONTACT AC VOLTAGE PROBE SP3000
CATALOG: MEMORY HICORDER MR8875
CURRENT SENSOR SERIES, CURRENT PROBE SERIES
DECLARATION OF CONFORMITY
MEMORY HICORDER MR8875 [100KB]
OTHERS
MEASURING INSTRUMENTS FOR THE AUTOMOTIVE MARKET
OPTIONS
500 A to 5000 A
*For commercial power lines, 50/60 Hz
CLAMP ON PROBE 9018-50
• Excellent phase characteristics • 40 Hz to 3 kHz • 10 to 500A AC • 0.2V AC/range output • φ 46 mm (1.81 in) core dia.
CLAMP ON PROBE 9132-50
• Use for level measurement • 40 Hz to 1 kHz • 20 to 1000A AC • 0.2 V AC/range output • φ 55 mm (2.17 in) core dia.
AC FLEXIBLE CURRENT SENSOR CT9667
• 10 Hz to 20 kHz (±3dB) • 5000 A/ 500 A AC rated input • 500 mV/f.s. output • φ 100 mm (3.94 in) core dia. to φ 254 mm (10.00 in), 3 loop diameters
AC/DC current input
AC/DC CURRENT SENSOR CT7636
・ DC to 10kHz (-3dB) ・Rated 600 A AC/DC ・ 1mV/A output ・φ 33 mm (1.30 in) core dia.
AC/DC CURRENT SENSOR CT7642
・ DC to 10kHz (-3dB) ・Rated 2000 A AC/DC ・ 0.1mV/A output ・φ 55 mm (2.17 in) core dia.
AC/DC AUTO-ZERO CURRENT SENSOR CT7731
・ DC to 5 kHz (-3dB) ・ Rated 100 A AC/DC ・ φ 33 mm (1.30 in) core dia.
AC/DC AUTO-ZERO CURRENT SENSOR CT7736
・ DC to 5 kHz (-3dB) ・ Rated 600 A AC/DC ・φ 33 mm (1.30 in) core dia
AC/DC AUTO-ZERO CURRENT SENSOR CT7742
・ DC to 5 kHz (-3dB) ・ Rated 2000 A AC/DC ・φ 55 mm (2.17 in) core dia.
DISPLAY UNIT CM7290
• Use with CT7000 series Current sensor • DCA, ACA, (DC+AC)A, frequency • Output to oscilloscopes: WAVE, RMS, PEAK, Hz • Power supply for single sensor
AC/DC CURRENT SENSOR CT7631
・ DC to 10kHz (-3dB) ・Rated 100 A AC/DC ・ 1mV/A output ・φ 33 mm (1.30 in) core dia.
Case
CARRYING CASE C1004
For the MR8875, includes compartment for options, hard trunk type
Connection Options
* L9217: for motor analysis input
CONNECTION CORD L9217
Cord has insulated BNC connectors at both ends, 1.6 m (5.25 ft) length
Current Input 2000A AC/DC
* The CT9920 is necessary for connecting the current sensor with HIOKI PL14 to the PW3390
AC/DC CURRENT SENSOR CT7642
・ DC to 10kHz (-3dB) ・Rated 2000 A AC/DC ・ 0.1mV/A output ・φ 55 mm (2.17 in) core dia.
AC/DC AUTO-ZERO CURRENT SENSOR CT7742
・ DC to 5 kHz (-3dB) ・ Rated 2000 A AC/DC ・φ 55 mm (2.17 in) core dia.
High voltage measurement
* Maximum input-to-ground rated voltages fall within these products’ specifications ranges (and do not affect the connected input units)
DIFFERENTIAL PROBE P9000
• Waveform only for exclusive use with Memory HiCorders (P9000-01) or waveform/RMS value switchable (P9000-02) • For use with input of up to 1 kV AC/DC • Requires separate power supply
AC ADAPTER Z1008
100 to 240V AC
Input cable (A)
*Voltage is limited to the specifications of the input modules in use.
CONNECTION CORD L9790
• Flexible φ 4.1 mm (0.16 in) thin dia. • Cable allowing for up to 600 V input • 1.8 m (5.91 ft) length
GRABBER CLIP 9790-02
Red/black set attaches to the ends of the Connection Cord L9790
ALLIGATOR CLIP L9790-01
Red/black set attaches to the ends of the Connection Cord L9790
CONTACT PIN 9790-03
Red/black set attaches to the ends of the Connection Cord L9790
Input cable (B)
*Voltage is limited to the specifications of the input modules in use.
CONNECTION CORD L9198
•φ 5.0 mm (0.20 in) dia. •Cable allows for up to 300 V input •1.7 m (5.58 ft) length •Small alligator clip
Input cable (F)
* Voltage input via banana terminals limited by the voltage specifications of the respective input unit.
CONNECTION CABLE SET L4940
Banana plug – banana plug, 1.5 m (4.92 ft) length, red/black each 1
EXTENSION CABLE SET L4931
Expands the length of the cable with banana plug, 1.5 m (4.92 ft) length
ALLIGATOR CLIP SET L4935
Attaches to the tip of the banana plug cable, CAT IV 600V, CAT III 1000V
BUS BAR CLIP SET L4936
Attaches to the tip of the banana plug cable, CAT III 600V
MAGNETIC ADAPTER SET L4937
Attaches to the tip of the banana plug cable, CAT III 1000V
Interface Cables
LAN CABLE 9642
Straight Ethernet cable, supplied with straight to cross conversion adapter, 5 m (16.41 ft) length
Leak Current
*For commercial power lines, 50/60 Hz
CLAMP ON LEAK HiTESTER 3283
• True RMS • AC leak current and load current testing • 10 mA leak current range with 10 µA resolution • Load current up to 200 A
AC ADAPTER 9445-02
For USA, 100 to 240 V AC, 9 V/ 1 A
OUTPUT CORD 9094
3.5 mm (0.14 in) dia. mini plug to banana, 1.5 m (4.92 ft) length
AC ADAPTER 9445-03
For EU 100 to 240 V AC, 9 V/ 1 A
Logic signal measurement
* Only the small terminal types can be used. * The 9323 is not required for the small-terminal types 9327, 9320-01, 9321-01 and MR9321-01.
LOGIC PROBE 9320-01,9320
• 4 channels for contact voltage signals • 500ns response • Miniature terminal type
LOGIC PROBE MR9321,MR9321-01
• 4 isolated channels • ON/OFF detection of AC/DC voltage • Large terminal type
Non-contact Voltage measuring
AC VOLTAGE PROBE SP9001
Sold individually
NON-CONTACT AC VOLTAGE PROBE SP3000
Sold individually
NON-CONTACT AC VOLTAGE PROBE SP3000-01
• Supports φ1mm to 2.5mm covered wires • 10Hz to 100kHz frequency bandwidth • 5Vrms 14Vp-p rated measurement voltage
Options for Differential Probes
Can also be used with accessories such as L4936/L4937/L4931 as available for other testers.
GRABBER CLIP 9243
Attaches to the tip of the banana plug cable, Red/ Black: 1 each, 196 mm (7.72 in) length, CAT III 1000 V
Other options for Input
CAN CABLE 9713-01
For the MR8904(MR8875), 8910, Unprocessed on one end, 1.8 m (5.91 ft) length
CONNECTION CORD L9217
Cord has insulated BNC connectors at both ends, 1.6 m (5.25 ft) length
CONVERSION ADAPTER 9199
Receiving side banana, output BNC terminal
PC Software
WAVE PROCESSOR 9335
• Convert data, print and display waveforms
Plug-in input modules
*Input cords are not included. Please purchase them separately. *When using 9709 with Current Unit 8971, a total of 7 current probes can be used.
ANALOG UNIT MR8901
4ch, Voltage measurement, DC to 100kHz bandwidth
VOLTAGE/TEMP UNIT MR8902
15ch, Voltage measurement, Thermocouple measurement
STRAIN UNIT MR8903
4ch, Voltage measurement, Strain gauge converter input, Conversion cable included
CAN UNIT MR8904
Up to 15 analog channels each equivalent to a 16-bit analog signal, and up to 16 logic channels each equivalent to a 1-bit logic signal
ANALOG UNIT MR8905
2ch, High-voltage DC/RMS measurement, DC to 100kHz bandwidth
Power supply
*AC adapter is bundled with the LR8410-20, LR8510/8511, LR8450, LR8450-01
AC ADAPTER Z1002
For main unit, 100 to 240 V AC
BATTERY PACK Z1003
NiMH, Charges while installed in the main unit
AC ADAPTER Z1008
100 to 240V AC
Storage media
Precaution on purchasing memory device
Use only the memory device sold by HIOKI. Compatibility and performance are not guaranteed for memory device made by other manufacturers. You may be unable to read from or save data to such devices.
SD MEMORY CARD 2GB Z4001
2 GB capacity
SD MEMORY CARD Z4003
8 GB capacity
Up to 1000 A (High precision)
*A separate power supply (CT955x) is required in order to use a high-precision current sensor. *Only sensors with ME15W (12-pin) terminals (-05 type) can be connected to the CT955x. *The separately available CONVERSION CABLE CT9900 is required in order to use a sensor with a PL23 (10-pin) terminal.
AC/DC CURRENT SENSOR 9709
• DC to 100kHz • Phase: DC to 100kHz • Rated 500A • 2V/500A output • φ 36 mm (1.42 in) core dia.
AC/DC CURRENT PROBE CT6845
• DC to 100 kHz • 500 A AC/DC rated • 4 mV/A output • φ 50 mm (1.79 in) core dia.
AC/DC CURRENT PROBE CT6844
• DC to 200 kHz • 500 A AC/DC rated • 4 mV/A output • φ 20 mm (0.79 in) core dia.
AC/DC CURRENT PROBE CT6846
• DC to 20 kHz • 1000 A AC/DC rated • 2 mV/A output • φ 50 mm (1.79 in) core dia.
Up to 200 A (High precision)
* To connect to the Probe1 input terminal (HIOKI ME15W terminal)
AC/DC CURRENT SENSOR CT6862
• DC to 1MHz, Phase: DC to 300kHz • Rated 50A • 2V/50 A output • φ 24 mm (0.94 in) core dia.
AC/DC CURRENT SENSOR CT6863
• DC to 500 kHz, Phase: DC to 300kHz • Rated 200A • 2V/200A output • φ 24 mm (0.94 in) core dia.
AC/DC CURRENT PROBE CT6841
• Frequency characteristics DC to 1 MHz, 20A AC/DC rated, 0.1 V/A output • φ 20 mm (0.79 in) core dia.
AC/DC CURRENT PROBE CT6843
• Frequency characteristics DC to 500 kHz, 200A AC/DC rated, 0.01 V/A output • φ 20 mm (0.79 in) core dia.
CLAMP ON SENSOR 9272
• 1Hz to 100kHz • Phase: 5Hz to 50kHz • Rated 20A or 200A • 2V/20A, 2V/200A output • φ 46 mm (1.81 in) core dia.
Voltage Input
*The L1000 is bundled with PQ3198 *Please inquire about voltage cord extension
GRABBER CLIP 9243
Attaches to the tip of the banana plug cable, Red/ Black: 1 each, 196 mm (7.72 in) length, CAT III 1000 V
EXTENSION CABLE SET L4931
Expands the length of the cable with banana plug, 1.5 m (4.92 ft) length