DESCRIPTION

The Hioki SS7012 is a compact DC signal source and calibrator that is used to perform maintenance or loop tests of instrumentation systems and can be operated from a computer via a USB cable. It can also be used to calibrate thermometers and measure DC voltage and DC current.

MODEL NO. (ORDER CODE)

SS7012

Note: Use of the AC Adapter and /or rechargeable batteries and dedicated charger is recommended

CE
USB 1.1

KEY FEATURES

• Improve stability and reduce calibration costs compared with the previous HIOKI model
• For instrumentation systems (4 – 20 mA) and loop testing
• Check temperature control equipment and electric distribution
• 8 types of thermocouples to test thermoelectric power generation
• Ideal for electrical device evaluating and routine maintenance of production equipment such as calibrators
• Use the max. 25 mA DC sink as an electric load

BASIC SPECIFICATIONS (ACCURACY GUARANTEED FOR 1 YEAR, POST-ADJUSTMENT ACCURACY GUARANTEED FOR 1 YEAR)[GENERATION FUNCTIONS]

Circuit methodBipolar sink and source
Constant voltage2.5 V: 0 to ±2.5000 V (±0.03 % of setting ±300 μV, 100 μV resolution)
25 V: 0 to ±25.000 V (±0.03 % of setting ±3 mV, 1 mV resolution)
Constant current25 mA: 0 to ±25.000 mA (±0.03 % of setting ±3 μA, 1 μA resolution)
Thermoelectric power generationK: at TC: 0 ˚C, -174.0 to 1372.0 ˚C (±0.05 % of setting ±0.5 ˚C, 0.1 ˚C resolution), Other types: E, J, T, R, S, B, N selectable
Thermoelectric power generationK: at TC: RJ, -174.0 to 1372.0 ˚C (±0.05 % of setting ±1.0 ˚C, 0.1 ˚C resolution), Other types: E, J, T, R, S, B, N selectable
Standard resistance (Rs)100 Ω (±0.2 Ω)
Automatic generationNumber of memory steps: 20, Interval time: 1 to 99 sec (at CV, CC, TC mode)

[MEASUREMENT FUNCTIONS]

Voltage2.5 V: 0 to ±2.8000 V (±0.03 % rdg. ±300 μV, 100 μV resolution, 1 MΩ input resistance)
25 V: 0 to ±28.000 V (±0.03 % rdg. ±3 mV, 1 mV resolution, 1 MΩ input resistance)
Current25 mA: 0 to ±28.000 mA (±0.03 % rdg. ±3 μA, 1 μA resolution, smaller than 30 Ω input resistance)
Temperature-25.0 to 80.0 ˚C (±0.5 ˚C at 23 ±5 ˚C, 0.1 ˚C resolution, use with the RJ sensor 9184)
Sampling rateApprox. 1.67 times/sec

[GENERAL FUNCTIONS]

Additional functionsZero adjustment, Overflow display, USB communication, Monitor
Power supplyAC adapter 9445-02/03 (100 to 240 V AC 50/60 Hz, 9 VA),
Ni-MH battery HR6 × 4, 6 VA, (fully charged 2500 mAh Ni-MH batteries: 170 minutes continuous use), or LR6 (AA) alkaline battery × 4, 6 VA
Dimensions and mass104 mm (4.09 in) W × 180 mm (7.09 in) H × 58 mm (2.28 in) D, 660 g (23.3 oz) (including LR6 × 4 batteries)
AccessoriesInput cord 9168 ×1, Test lead L9170-10 ×1, Fuse ×1, LR6 (AA) alkaline battery ×4, Instruction manual ×1

CATALOGS

DC SIGNAL SOURCE SS7012 

DOWNLOAD

DECLARATION OF CONFORMITY

DC SIGNAL SOURCE SS7012 [100KB] 

DOWNLOAD

OPTIONS

Cables

INPUT CORD 9168

70 cm (2.30 ft) length

Input Probes

*L9170-10 is a bundled accessory. *Requires the 9704 to connect a Clamp-on probe

TEST LEAD L9170-10

70 cm (2.30 ft) length

Leak Current

*For commercial power lines, 50/60 Hz

AC ADAPTER 9445-02

For USA, 100 to 240 V AC, 9 V/ 1 A

AC ADAPTER 9445-03

For EU 100 to 240 V AC, 9 V/ 1 A

Options

TEMPERATURE PROBE 9184

For reference contact compensation

CARRYING CASE 9380

For storing the main body only, soft type

COMMUNICATION PACKAGE SS9000

USB cable, USB driver software included

Other options

*C0203 is bundled.

CARRYING CASE 9782

Includes compartment for options, resin-coated

Categories

Social Links