DC Voltage and Current Signal Generator and Tester for Routine Maintenance of Standard Devices
DESCRIPTION
The Hioki SS7012 is a compact DC signal source and calibrator that is used to perform maintenance or loop tests of instrumentation systems and can be operated from a computer via a USB cable. It can also be used to calibrate thermometers and measure DC voltage and DC current.
MODEL NO. (ORDER CODE)
SS7012 |
---|
Note: Use of the AC Adapter and /or rechargeable batteries and dedicated charger is recommended
KEY FEATURES
• Improve stability and reduce calibration costs compared with the previous HIOKI model
• For instrumentation systems (4 – 20 mA) and loop testing
• Check temperature control equipment and electric distribution
• 8 types of thermocouples to test thermoelectric power generation
• Ideal for electrical device evaluating and routine maintenance of production equipment such as calibrators
• Use the max. 25 mA DC sink as an electric load
BASIC SPECIFICATIONS (ACCURACY GUARANTEED FOR 1 YEAR, POST-ADJUSTMENT ACCURACY GUARANTEED FOR 1 YEAR)[GENERATION FUNCTIONS]
Circuit method | Bipolar sink and source |
---|---|
Constant voltage | 2.5 V: 0 to ±2.5000 V (±0.03 % of setting ±300 μV, 100 μV resolution) 25 V: 0 to ±25.000 V (±0.03 % of setting ±3 mV, 1 mV resolution) |
Constant current | 25 mA: 0 to ±25.000 mA (±0.03 % of setting ±3 μA, 1 μA resolution) |
Thermoelectric power generation | K: at TC: 0 ˚C, -174.0 to 1372.0 ˚C (±0.05 % of setting ±0.5 ˚C, 0.1 ˚C resolution), Other types: E, J, T, R, S, B, N selectable |
Thermoelectric power generation | K: at TC: RJ, -174.0 to 1372.0 ˚C (±0.05 % of setting ±1.0 ˚C, 0.1 ˚C resolution), Other types: E, J, T, R, S, B, N selectable |
Standard resistance (Rs) | 100 Ω (±0.2 Ω) |
Automatic generation | Number of memory steps: 20, Interval time: 1 to 99 sec (at CV, CC, TC mode) |
[MEASUREMENT FUNCTIONS]
Voltage | 2.5 V: 0 to ±2.8000 V (±0.03 % rdg. ±300 μV, 100 μV resolution, 1 MΩ input resistance) 25 V: 0 to ±28.000 V (±0.03 % rdg. ±3 mV, 1 mV resolution, 1 MΩ input resistance) |
---|---|
Current | 25 mA: 0 to ±28.000 mA (±0.03 % rdg. ±3 μA, 1 μA resolution, smaller than 30 Ω input resistance) |
Temperature | -25.0 to 80.0 ˚C (±0.5 ˚C at 23 ±5 ˚C, 0.1 ˚C resolution, use with the RJ sensor 9184) |
Sampling rate | Approx. 1.67 times/sec |
[GENERAL FUNCTIONS]
Additional functions | Zero adjustment, Overflow display, USB communication, Monitor |
---|---|
Power supply | AC adapter 9445-02/03 (100 to 240 V AC 50/60 Hz, 9 VA), Ni-MH battery HR6 × 4, 6 VA, (fully charged 2500 mAh Ni-MH batteries: 170 minutes continuous use), or LR6 (AA) alkaline battery × 4, 6 VA |
Dimensions and mass | 104 mm (4.09 in) W × 180 mm (7.09 in) H × 58 mm (2.28 in) D, 660 g (23.3 oz) (including LR6 × 4 batteries) |
Accessories | Input cord 9168 ×1, Test lead L9170-10 ×1, Fuse ×1, LR6 (AA) alkaline battery ×4, Instruction manual ×1 |
CATALOGS
DC SIGNAL SOURCE SS7012
DECLARATION OF CONFORMITY
DC SIGNAL SOURCE SS7012 [100KB]
OPTIONS
Cables
INPUT CORD 9168
70 cm (2.30 ft) length
Input Probes
*L9170-10 is a bundled accessory. *Requires the 9704 to connect a Clamp-on probe
TEST LEAD L9170-10
70 cm (2.30 ft) length
Leak Current
*For commercial power lines, 50/60 Hz
AC ADAPTER 9445-02
For USA, 100 to 240 V AC, 9 V/ 1 A
AC ADAPTER 9445-03
For EU 100 to 240 V AC, 9 V/ 1 A
Options
TEMPERATURE PROBE 9184
For reference contact compensation
CARRYING CASE 9380
For storing the main body only, soft type
COMMUNICATION PACKAGE SS9000
USB cable, USB driver software included
Other options
*C0203 is bundled.
CARRYING CASE 9782
Includes compartment for options, resin-coated